What to Do If TLR4 and NF-κB Bands on WB Are Reversed? Secondary Antibody Diluted, Is Actin Normal?

    Signal inversion (i.e., bands appearing lighter than the background) for TLR4 and NF-κB in Western blotting—despite appropriate secondary antibody dilution and normal actin control—may result from multiple underlying factors:

     

    Excessive Secondary Antibody Concentration

    If reducing the secondary antibody concentration fails to resolve the issue, further dilution or substitution with an alternative secondary antibody may be warranted to minimize background signal amplification.

     

    Overconcentration of Primary Antibody

    Excess primary antibody can increase background noise or saturate signal detection. Optimization through serial dilution of the primary antibody may help clarify band visualization.

     

    Prolonged Antibody Incubation

    Extended incubation times for either primary or secondary antibodies may enhance nonspecific interactions, increasing background intensity and potentially inverting the signal. Reducing incubation durations may mitigate this.

     

    Inadequate Washing

    Insufficient washing following antibody incubations may leave unbound antibodies on the membrane, leading to elevated background and poor signal-to-noise ratio. Additional or longer washing steps using appropriate buffers can improve clarity.

     

    Protein Overloading

    Loading excessive amounts of total protein can cause signal oversaturation and non-linear chemiluminescent responses, manifesting as signal inversion. Adjusting the protein input to within the linear detection range is advised.

     

    Suboptimal Blocking

    Incomplete membrane blocking can allow nonspecific binding of antibodies, contributing to uneven signal distribution. Optimization may involve increasing blocking time, concentration, or selecting a different blocking reagent (e.g., BSA vs. milk).

     

    Excessive Exposure Time

    In chemiluminescent detection, overexposure can saturate strong signals while diminishing contrast, resulting in bands that appear inverted. Adjusting exposure time or using a lower sensitivity setting may restore proper visualization.

     

    MtoZ Biolabs, an integrated chromatography and mass spectrometry (MS) services provider.

    Related Services

    Western Blot Analysis Service

Submit Inquiry
Name *
Email Address *
Phone Number
Inquiry Project
Project Description *

 

How to order?


/assets/images/icon/icon-message.png

Submit Inquiry

/assets/images/icon/icon-return.png