• Home
  • Biopharmaceutical Research Services
  • Multi-Omics Services
  • Support
  • /assets/images/icon/icon-email-2.png

    Email:

    info@MtoZ-Biolabs.com

    Cryo-EM for Filaments Structure Characterization Service

      Cryo-EM for Filaments Structure Characterization Service focuses on high-resolution structural analysis of filamentous biomacromolecules, including cytoskeletal fibers, viral filaments, and protein aggregates. Filamentous structures are pivotal in cellular support, intracellular transport, signal transduction, and disease progression. Accurate elucidation of their 3D architecture is critical for uncovering functional mechanisms, understanding disease pathogenesis, and advancing the development of novel biomaterials.

       

      Given the inherent challenges posed by filamentous molecules—such as high heterogeneity, significant flexibility, and dispersed orientations—traditional methods like X-ray crystallography and nuclear magnetic resonance (NMR) often fall short. Cryo-electron microscopy (Cryo-EM) has thus emerged as a leading technology for structural analysis of filaments. By combining advanced strategies such as single particle analysis (SPA) and helical reconstruction, Cryo-EM captures diverse conformations under near-native conditions and achieves near-atomic resolution, enabling detailed characterization of filamentous assemblies. This approach has been successfully applied to microtubules, actin filaments, viral capsid proteins, amyloid fibrils, and newly designed biomaterials.

       

      MtoZ Biolabs proudly offers the Cryo-EM for Filaments Structure Characterization Service to deliver comprehensive solutions from sample preparation and Cryo-EM data acquisition to 3D reconstruction and in-depth structural analysis. Our service empowers researchers to accelerate innovation across life sciences and material sciences.

       

      Services at MtoZ Biolabs

      Through the Cryo-EM for Filaments Structure Characterization Service, MtoZ Biolabs provides tailored, end-to-end solutions for a wide range of filamentous samples, including but not limited to:

      1. Purification and preparation of filamentous samples (e.g., microtubules, actin filaments, viral filaments, amyloid fibrils)

      2. Negative staining electron microscopy pre-screening

      3. Cryo-sample vitrification

      4. High-throughput Cryo-EM data collection

      5. Single Particle Analysis (SPA) and Helical Reconstruction

      6. Near-atomic resolution 3D reconstruction and structural interpretation

       

      By integrating advanced image processing algorithms with cutting-edge Cryo-EM technologies, MtoZ Biolabs enables researchers to precisely capture the ultrastructural details of filamentous assemblies and gain deep insights into their structural and functional mechanisms.

       

      Service Advantages

      Partnering with MtoZ Biolabs through the Cryo-EM for Filaments Structure Characterization Service provides access to multiple competitive advantages:

      ·  Broad Sample Compatibility: Capable of handling diverse filament types, from flexible polymers to ordered helical

      ·  High-Resolution Imaging: Leveraging the latest direct electron detectors and high-end Cryo-EM platforms to achieve superior image clarity and resolution.

      ·  Advanced Image Processing Expertise: Supporting helical reconstruction, local refinement, and heterogeneous state analysis using state-of-the-art computational tools.

      ·  Extensive Sample Preparation Experience: Proficient in filament purification, negative-stain screening, and optimized vitrification tailored to filament-specific properties.

      ·  Customized Project Execution: Flexibly adapting acquisition strategies and processing workflows to align with sample characteristics and research objectives.

      ·  One-Time-Charge: Our pricing is transparent, no hidden fees or additional costs.

       

      Applications

      The Cryo-EM for Filaments Structure Characterization Service supports a broad range of scientific inquiries, including:

      ·  Cytoskeleton Research: Detailed analysis of actin filaments, microtubules, and other cytoskeletal components to elucidate cellular morphology and motility mechanisms.

      ·  Neuroscience: Investigation of neuronal microtubules and neurofilaments in the context of neurodegenerative diseases.

      ·  Virology: Structural dissection of viral filaments and capsid architectures to guide antiviral drug development.

      ·  Protein Aggregation Studies: Insight into amyloid fibril formation relevant to Alzheimer's disease, Parkinson's disease, and related conditions.

      ·  Biomaterials Innovation: Structural characterization of novel filamentous biomaterials to drive advances in biomedical applications.

       

      Case Study

      Case 1: Cryo-EM Elucidation of Cardiac Myosin Filament Structure Supporting Disease Mechanism Insights

      In a 2023 study, researchers employed Cryo-EM to resolve the near-atomic structure of human cardiac myosin filaments. This analysis revealed the spatial assembly of myosin, cardiac myosin-binding protein C (cMyBP-C), and titin within the filament core. Furthermore, three distinct myosin motor domain conformations and their interactions with cMyBP-C and titin were identified, providing novel mechanistic insights into super-relaxed states, length-dependent activation, and genetic mutation-induced cardiac diseases. This work exemplifies the power of Cryo-EM in characterizing filamentous protein complexes.

       

      1917130185149894656-cryo-em-for-filaments-structure-characterization-service1.jpg

      Dutta, D. et al. Nature.2023.

       

      MtoZ Biolabs provides professional Cryo-EM for Filaments Structure Characterization Service to support researchers in efficiently resolving the 3D structures of filamentous protein complexes and accelerating the exploration of functional mechanisms and disease research.

       

      FAQ

      Q1: Why choose Cryo-EM for filamentous structure characterization?

      Cryo-EM enables visualization under near-native conditions, avoiding artifacts induced by dehydration in traditional electron microscopy. For dynamic, heterogeneous, and non-crystallizable filamentous samples, Cryo-EM combined with SPA or Helical Reconstruction strategies delivers reliable, high-resolution structures. The Cryo-EM for Filaments Structure Characterization Service by MtoZ Biolabs ensures accurate and physiologically relevant insights into filament architecture.

       

      Q2: How does helical reconstruction differ from single particle analysis for filament studies?

      Helical reconstruction is optimal for regularly ordered filaments like viral fibers and cytoskeletal structures, while SPA is more suited for flexible or non-periodic filaments. Within the Filaments Structure Characterization Service, MtoZ Biolabs strategically selects the most appropriate approach to maximize reconstruction accuracy based on sample properties.

       

      If you seek to advance your filamentous structural research, MtoZ Biolabs' Cryo-EM for Filaments Structure Characterization Service offers the comprehensive expertise and technological excellence needed to transform your scientific discoveries. Contact us today to customize your project plan and experience the future of high-resolution filament structure analysis.

    Submit Inquiry
    Name *
    Email Address *
    Phone Number
    Inquiry Project
    Project Description *

     

    How to order?


    /assets/images/icon/icon-message.png

    Submit Inquiry

    /assets/images/icon/icon-return.png