Can CD Detection Solution Be an Organic Solvent? Why Do Peaks Split with 0.01M Phosphate Buffer in Chromatography
-
Check the buffer’s pH and ionic strength to ensure suitability for your chromatography analysis.
-
Test extraction with phosphate buffers of varying concentrations or pH values to determine if peak splitting persists.
-
If feasible, use an alternative type of chromatographic column to assess whether peak splitting still occurs.
Circular Dichroism (CD) detection is a spectroscopic technique commonly used to investigate the secondary structure and conformational changes of biological macromolecules such as proteins and nucleic acids. In CD detection, both the sample and the solvent within the solution influence the resulting spectra. Therefore, selecting an appropriate solvent is crucial.
Requirements for CD detection solution:
1. No Absorption
To minimize background signals, the solvent should be transparent within the wavelength range of interest. This is especially critical in the near-ultraviolet region, where many organic solvents exhibit significant absorption.
2. No Impact on the Sample
The solvent must not alter the sample’s structure or biological activity, particularly when studying proteins or other biological macromolecules.
3. Stability
Certain solvents may degrade or become unstable over time or under specific conditions, which could compromise the reliability of CD measurements.
While some organic solvents can be used for CD detection, their selection must be done with care. Water, methanol, ethanol, and acetonitrile are frequently employed as CD solvents because they are transparent across most relevant wavelengths. However, organic solvents such as dichloromethane and tetrahydrofuran exhibit strong absorption in the ultraviolet region, making them unsuitable for CD measurements.
When selecting a solvent, it is essential to consider its absorbance properties across the relevant wavelength range and ensure it does not interfere with or alter the sample. For optimal accuracy, it is advisable to perform CD measurements in multiple solvents and compare the results.
If peak splitting or bifurcation is observed in liquid chromatography following sample extraction with 0.01M phosphate buffer, several factors may contribute:
1. Ionic Strength and pH Effects
The ionic strength and pH of the phosphate buffer can influence the hydrophilic and hydrophobic interactions of molecules in the sample, thereby altering their behavior on the chromatographic column and causing peak splitting.
2. Formation of Salts
Phosphate may react with certain sample components to form salts with different retention times and interaction profiles, resulting in peak splitting.
3. Sample Impurities
Phosphate buffer may co-extract impurities distinct from those present in the mobile phase, which could interact with the primary components on the column and contribute to peak splitting.
4. Buffer Effects on the Column
If the chromatographic column is sensitive to phosphate, the buffer may disrupt chemical bonding within the column, reducing performance and causing peak splitting.
5. Potential Changes in Sample Composition
Different extraction methods may yield variations in sample composition, which can also account for peak splitting.
To pinpoint the exact cause of peak splitting, consider the following approaches:
MtoZ Biolabs, an integrated chromatography and mass spectrometry (MS) services provider.