5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic Acid Analysis Service

    5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid, also known as Leukotriene D4 (LTD4), is a biologically significant eicosanoid derived from arachidonic acid, playing an essential role in inflammation and immune response regulation. This molecule is part of the cysteinyl-leukotriene (CysLTs) family, which is known for its involvement in allergic reactions and inflammatory processes. Structurally, 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid features a hydroxyl group at the 5S position and a cysteinylglycinyl moiety attached to the 6R position, making it a unique bioactive lipid involved in cellular signaling.

     

    This metabolite is generated through the lipoxygenase pathway, where arachidonic acid undergoes enzymatic modifications to form various cysteinyl-leukotrienes. These compounds are critical mediators of inflammatory responses, particularly in conditions like asthma, allergic rhinitis, and cardiovascular diseases. As a key participant in the leukotriene pathway, 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid interacts with CysLT receptors, influencing bronchoconstriction, vascular permeability, and immune cell recruitment to sites of inflammation. The accurate measurement of this compound is crucial for understanding its role in inflammation and for exploring its potential as a biomarker in allergic and cardiovascular conditions. Additionally, quantifying this eicosanoid aids in the development of therapeutic strategies targeting cysteinyl-leukotriene pathways.

     

    1843891622589878272-TheStructureof5S-hydroxy-6R-S-cysteinylglycinyl-7E,9E,11Z,14Z-eicosatetraenoicAcid.png

     

    Figure 1. The Structure of 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic Acid

     

    MtoZ Biolabs, an integrated Chromatography and Mass Spectrometry (MS) Services Provider, providing advanced proteomics, metabolomics, and biopharmaceutical analysis services to researchers in biochemistry, biotechnology, and biopharmaceutical fields. Our ultimate aim is to provide more rapid, high-throughput, and cost-effective analysis, with exceptional data quality and minimal sample consumption. MtoZ Biolabs offers a specialized 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic Acid Analysis Service. Our team of experts can help you:

    • Provide precise quantification of 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid using the state-of-the-art LC-MS/MS platform.
    • Perform comprehensive metabolic profiling that can reveal significant changes in metabolism.
    • Identify potential biomarkers associated with pathological conditions.

     

    Analysis Workflow

     

    1843892451640201216-Workflowfor5S-hydroxy-6R-S-cysteinylglycinyl-7E,9E,11Z,14Z-eicosatetraenoicAcidAnalysisService.png

     

    Service Advantages

    1. Advance Analysis Platform

    MtoZ Biolabs established an advanced 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid analysis service platform, guaranteeing reliable, fast, and highly accurate analysis service.

     

    2. One-Time-Charge

    Our pricing is transparent, no hidden fees or additional costs.

     

    3. High-Data-Quality

    Deep data coverage with strict data quality control. AI-powered bioinformatics platform integrate all 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic acid analysis service data providing clients with a comprehensive data report.

     

    4. Fast Turnaround

    The process from sample handling to report generation is efficient, shortening the analysis cycle.

     

    Applications

    • Disease Diagnosis
    • Drug Efficacy Studies
    • Metabolic Pathway Studies
    • Biomarker Discovery

     

    Sample Submission Requirements

    1. Sample Types

    Serum, plasma, urine, tissues, and other biological samples. It is recommended to prepare at least 3 biological replicates for each sample type.

     

    2. Sample Volume

    • Animal tissue ≥ 100 mg
    • Plant tissue ≥ 200 mg
    • Serum/ Plasma ≥ 200 μL
    • Urine ≥ 2 mL

     

    3. Storage and Shipping

    Samples should be stored at -80℃ and shipped with dry ice. Avoid repeated cycles of freezing and thawing

     

    Note: Please provide details on sample collection and handling.

     

    Deliverables

    1. Comprehensive Experimental details (Materials, Instruments, and Methods, etc.)

    2. Relevant Liquid Chromatography and Mass Spectrometry Parameters

    3. Detailed Information on 5S-hydroxy-6R-(S-cysteinylglycinyl)-7E,9E,11Z,14Z-eicosatetraenoic Acid

    4. Raw Data

    5. Custom Analysis Report

     

    MtoZ Biolabs is committed to accelerating your research with our comprehensive metabolomics services. Trust us to deliver accurate, reliable, and timely results for your analysis needs.

Submit Inquiry
Name *
Email Address *
Phone Number
Inquiry Project
Project Description *

 

How to order?


/assets/images/icon/icon-message.png

Submit Inquiry

/assets/images/icon/icon-return.png